2016年11月3日星期四

Basic structure of centrifugal pump

The basic structure of the centrifugal pump is composed of eight parts, namely: impeller, pump, pump cover, retaining ring, pump shaft, bearings, seal ring, stuffing box, axial force balance device.
1, the impeller is the center of the centrifugal pump some of its high-speed output power.
2, the pump body, also known as pump shell, which is the main pump. To support the fixed effect, and with the device bearing bracket connected.
3, the effect of the shaft is connected by the coupling and the motor, the motor torque to the impeller, so it is the primary component of mechanical energy transfer
4, sealing ring, also known as leakage ring.
5, mainly by packing stuffing, not to pump the water flow to the outside to not let the outside air into the pump. Always keep the vacuum inside the pump! When the pump shaft and the filler conflict heat will depend on the water sealing tube to fill the water seal ring to fill the cooling!
6, the axial force balance device, in the centrifugal pump operation, because the liquid is in the low pressure into the impeller, and under high pressure out, so that the pressure on both sides of the impeller impingement, the direction of the thrust of the direction of axial thrust, will Causing the rotor to seize the axial movement, the occurrence of wear and oscillation, which should be set to axial thrust bearings, in order to balance the axial force.

Centrifugal pump use matters needing attention

Centrifugal pump use matters needing attention
Pump commissioning should meet the following requirements:
① the steering of the drive should be the same as the direction of the pump;
② to identify the pipeline pump and coaxial pump steering;
③ the fixed convergence of the parts should be no loose, smooth parts of the smoothing agent should be added to the standard and the number of equipment skill files should be consistent with the rules;
④ pre-smooth requirements of the site should be pre-smooth rules;
⑤ the appearance of the instructions, safety equipment should be active, accurate and reliable;
⑥ wheel car should be sensitive, no abnormal phenomenon;
⑦ high temperature pump should be carried out before the test run the pump preheat, the temperature should be increased uniformly, the hourly temperature rise should not be greater than 50 ℃; pump surface and the operating medium imported technology should not be greater than 40 ℃ temperature difference;
⑧ set up to eliminate the impact of convergence temperature equipment, set the bypass connection equipment supply cooling water.
Centrifugal pump operation should note the following points:
① stop the water run, do not adjust the suction inlet to reduce the displacement, to stop running at low flow rate;
② monitoring the operation process, completely hinder the packing box leakage, replace the packing box to use new packing;
③ to ensure that the mechanical seal with plenty of water erosion, water-cooled bearings to stop the use of excessive water flow;
④ smooth agent do not use too much;
⑤ according to the referral cycle to check. Establish operating records, including the number of hours of operation, packing adjustment and replacement, adding smoothing agent and other protection methods and time. On the centrifugal pump suction and discharge pressure, flow, input power, lotion and bearing temperature and oscillation conditions should be measured measurement records.
⑥ centrifugal pump host is relying on atmospheric pressure to lower the water pumped high, and the atmospheric pressure can only support the water column of about 10.3m, so the centrifugal pump from the surface of the host 12 meters can not work.

Centrifugal pump maintenance

Failure Analysis of Mechanical Seal for Centrifugal Pump
Centrifugal pump shutdown is mainly caused by the failure of mechanical seals formed. The failure of the performance are mostly leaked, leaked by the following reasons:
① dynamic ring sealing surface leakage, the main reasons are: end flatness, roughness does not reach the demand, or the appearance of scratches; end surface between the particulate matter, the formation of both ends can not be the same work; device is not in place, the method is not correct.
② compensation ring ring leakage, the main reasons are: gland deformation, preload force is not uniform; device is not correct; ring quality does not meet specifications; ring selection is wrong.
The actual use of the role of the seal component failure is the most part of the dynamic and static end of the ring, centrifugal pump seal dynamic, static ring face is a common failure of the surface representation of the main reasons:
① device sealing surface gap is too large, flushing fluid too late to take the heat of the deputy deputy of the conflict; flushing fluid leakage from the sealing surface gap, the formation of end surface overheating and damage.
② vaporization of liquid medium swells, so that both sides of the face by the vaporization of expansion and strong separation, when the two sealing surface of the force fit, the damage to the smooth surface and then form the surface appearance of overheating.
③ liquid medium, poor smoothness, coupled with operating pressure overload, the two sealing surface stare change is not synchronized. For example, high-speed pump speed is 20445r / min, the sealing surface of the middle diameter of 7cm, the line speed of the pump work up to 75m / s, when there is a sealing surface lag can not stalk rotation, instantaneous high temperature sealing surface damage.
④ seal flushing fluid orifice plate or filter blockage, the formation of water shortage, the mechanical seal failure.
In addition, the surface of the sliding surface of the sealing surface, the end surface of the gap when the gap caused by sealing element failure, the main reasons are:
① liquid medium is not clean, there are small particles of hard quality, high speed slide people sealing surface, the end surface scratches and failure.
② pump drive coaxial poor, the pump is open after the end of each revolution is shaking a collision, the work of the orbit is not concentric, forming end surface vaporization, overheating wear.
③ frequent hydraulic characteristics of the liquid medium led to oscillation pump group, the formation of sealing surface dislocation and failure.
Liquid medium on the sealing element corrosion, stress gathering, hard and soft data cooperation, erosion, auxiliary sealing 0-ring, V-ring, concave ring and liquid medium incompatibility, deformation and so on will form mechanical seal surface damage failure, Therefore, the way to analyze the damage to find out the root cause, to ensure long-term mechanical seal work.

Overview of sewage pumps

Sewage pump is a pump and motor piece, and at the same time into the liquid work under the pump products, and general horizontal or vertical sewage pump compared to sewage pump compact structure, small footprint. Large submersible pumps are usually equipped with automatic coupling device can be automatically installed, installation and maintenance is quite convenient. Small sewage pump can be installed free of charge, large sewage pump is generally equipped with automatic coupling device can be automatically installed, Continuous operation for a long time. Sewage pump As the pump and motor coaxial, shaft short, light weight of the rotating parts, so bear the load on the bearing (radial) is relatively small, life expectancy much longer than the average pump. There is no cavitation damage and irrigation water and other issues. In particular, the latter point to the operator to bring a great deal of convenience. Vibration and noise, the motor temperature is low, no pollution to the environment.

2016年11月1日星期二

Introduction of submersible sewage pump

WQ series submersible sewage pump is digesting and absorbing foreign advanced technology developed on the basis of success, a team with efficiency and prevent winding, no jam, automatic coupling, the advantages of high reliability and automatic control, solid particles and long fiber waste in lining, has the unique function.
This series of pump discharge water diameter of 50 ∽ 600 mm, flow 10 to 7000 m3 / h, head of 5 ∽ 60 m, 1.5 ~ 315 kw power, through the solid particle diameter of 20 ~ 145 mm.
Uses and features
WQ series submersible sewage pump is mainly used in municipal engineering, industrial, hospitals, buildings, hotels, restaurants and other industries. Used for lining with solid and all kinds of long fiber sludge, waste water, urban sewage (including the occasion of corrosive and erosive medium).
WQ series submersible sewage pump is small in size, compact structure, high efficiency, can according to user requirements for water level automatic control, and equipped with automatic protection device and the control cabinet, double guide rail automatic installation system, etc.
Conditions of use
1, motor rated voltage 380 v, 50 hz frequency three-phase ac power supply.
2, medium temperature does not exceed 40 oc.
3, conveying liquid medium PH value of 4 to 10.
4, transmission medium solid phase volume ratio under 2%.
5, medium density is less than 1.2 x 103 kg/m3
Structural characteristics of
WQ series submersible sewage pump compact structure, and set the various states, according to a protection device, the pump running safety and reliable.
1, the unique design of cable seal ruled out the cable leakage hidden trouble.
2, stator with F class insulation, equipped with thermal protection components.
More than 3, 18.5 KW pump adopts automatic circulating water cooling, to ensure the safe operation of the pumps in the lowest level state.
4, float switch installed at the bottom of the motor chamber under, implement guardianship for motor mechanical seal.
5, of the oil pump and motor chamber top with oil-water probe, implement guardianship for lateral pump mechanical seal, once leakage, control system will alarm protection.
6, bellows type double mechanical seal, the sealing material for tungsten carbide, silicon carbide and tungsten carbide, prevent water from entering the motor and ensuring safe and reliable operation of the motor.
7, vice impeller mechanical seal is used to balance the external pressure, prevent water into the oil chamber, so as to prolong the service life of electric pump.
8, impeller and unique design, big flow to through the long fiber and dirt, anti-clogging, winding, flow ability.
9, impeller and volute fitted with replaceable wear set between the bottom, keep the pump run at optimal efficiency.
The impeller design characteristics
In order to guarantee the smooth of the sewage through, must strengthen the impeller flow surface width, for large pump, can use double blade, three-blade; For a small pump, in the form of single (double) port, it is similar to a cross section bend with the same size, and very good flow characteristics. To avoid the water flow under the condition of low speed may cause jams, coil. This unique design of impeller passage with reasonable volute chamber, make wastewater in paper, textiles, bags and other materials can free pass. Impeller after dynamic and static balance, make the pump in the no-load test run and vibration are not produced in the process of loading.
Install and use
This company produces the diving sewage pump, pump and coaxial, compact structure, high efficiency, easy installation and maintenance, economic operation, strong adaptability, its installation method are mobile and fixed installation, fixed installation is divided into automatic coupling installation with fixed dry installed, installed mobile also called freestyle.

Deep well submersible pump selection considerations

1, the characteristics of the medium: the name of the medium, specific gravity, viscosity, corrosive, toxic, etc
2, medium contained in the diameter of the solid particles, the content (the mass or volume percentage)
3, medium temperature (℃)
4, need traffic
General industrial pump can be ignored in the process of pipeline system leakage, but affected by the change of flow must be considered. Agricultural use if it is determined by open channel water must also consider leakage and evaporation.
5, pressure, suction pressure exhaust the pool of pressure piping system pressure drop (head losses)
6, pipeline system data (diameter, length, types and number of suction piping fittings to pressure the pool geometry level, etc.) should also be made if necessary device characteristic curve in design layout piping should be paid attention to the following items:
A, reasonable choose pipe diameter pipe diameter under the same flow rate, flow velocity small resistance loss but high price pipe diameter moment lead to resistance losses increase sharply increase the selected pump lift installed with power increasing cost and operation cost are so from the perspective of technical and economic comprehensive consideration
B, discharge pipe and pipe joints should be considered are the biggest pressure
C, pipeline layout should decorate straight pipe to reduce as far as possible in the attachment and try to narrow the pipe length must turn the elbow bend radius should be 3 ~ 5 times the diameter of the pipe Angle is greater than 90 ℃ as much as possible
D, the discharge side of the pump must be installed with the valve (ball valve or valve, etc.) and check valve is used to adjust the point check valve of the pump valve when the fluid flow reversal can prevent reversal and pump to avoid water hammer blow (when liquid backflow produce huge pressure to reverse damage to the pump)
Second, determine the flow head
The determination of traffic
A, if the production process has given the smallest, normal and maximum flow should be taken into account by the maximum flow
B, if only in the production process should be considered normal flux left a certain margin For ns > 100 low flow the unpreparedness lift pump flow take 5% allowance for ns > 50 small flow high lift pump flow allowance take 50 or less 10% ns 100 pump flow allowance also take 5% or less of inferior quality and running conditions of the pump flow allowance shall be 10%
C, if the basic data only to weight rate should be converted to volume flow

Pipeline pump installation method

1, the shaft radial beat the equipment should be 0.04 mm or less, axial channeling momentum does not allow more than 0.1 mm;
2 sealing parts during the installation, equipment should be kept clean, sealed parts should be clean, the seals are intact, prevent the impurity and dust into the sealing parts;
3, during the installation process strictly forbid a touch attack, knock, lest make pay damage mechanical seal friction and the seal failure;
4, when installed in the sealing contact surface should be coated with a layer of clean machine oil, so as to smooth installation;
5, installing a static ring gland, tighten bolts must force uniform, ensure static ring end face and the axis of vertical requirements;
6, after the installation drive ring with the hand, can make the ring on the shaft flexible mobile, and have certain elasticity;
7, with the hand after installation plate moving axis, axis should be no weight feeling;
8, the equipment must be full of medium before operation, to prevent dry friction and make the seal failure;