2017年3月16日星期四

Routine maintenance of vertical multi - stage centrifugal pumps

In recent years, China's centrifugal pump industry has developed rapidly, benefiting from the continuous improvement of production technology in the centrifugal pump industry and the continuous expansion of the downstream demand market. The centrifugal pump industry is very optimistic about the development situation in the domestic and international markets.
    China's centrifugal pump industry is facing a new development situation, due to the increasing number of new entrants into the enterprise, the upstream raw material prices continue to rise, leading to lower profits in the industry, so China's centrifugal pump industry market competition is becoming increasingly fierce. In the face of this situation, the centrifugal pump industry industry enterprises should actively respond, focus on cultivating innovation ability, and constantly improve their own production technology, strengthen the competitive advantage, at the same time centrifugal pump industry enterprises should fully grasp the industry market trend, Continue to learn the industry's latest production technology, to understand the industry's national policies and regulations to grasp the same industry competitors in the development of the dynamic, the only way to enable enterprises to fully understand the industry's development and their own position in the industry, and to develop the right Development strategy to enable enterprises in the brutal competition in the market to obtain a leading edge.
    DL vertical multi-stage centrifugal pump is a kind of centrifugal pump, the pump used in the structure of the vertical, sub-form. So that vertical multi-stage centrifugal pump safe operation, smooth, long life, small footprint, safe and easy maintenance. Our company adopts the excellent hydraulic model with high efficiency and energy saving, so it has the advantages of high efficiency, wide range of performance and so on, and better meets the requirements of users. Vertical multi-stage centrifugal pump is suitable for industrial and urban water supply and drainage. Pressure, long-distance water, heating, bathroom, boiler heating and cooling cycle pressurization, air conditioning and refrigeration systems and water equipment and other occasions.
    DL vertical multi-stage centrifugal pump works and maintenance, when the multi-stage centrifugal pump motor drive shaft on the high-speed rotation of the impeller, filled with the liquid in the impeller under the action of centrifugal force from the impeller center along the blade between the flow channel Thrown around the impeller, because the liquid by the role of the blade, so that the pressure and speed increased at the same time, through the chute of the flow channel was cited to the next level of the impeller, so that once through all the impeller and guide shell, further So that the pressure of the liquid energy increases. After each impeller is superimposed on each step, a certain lift is obtained. Can be applied to industrial and urban water supply and drainage, high-level pressurized water, garden irrigation, heating and water cycle pressurization and equipment supporting multi-stage centrifugal pump is the flow medium (gas and liquid, it can be suspended particles and gas or liquid mixture) from The blade rotates the root (inlet) into the medium, and the medium relies on high-speed rotation of the blade to obtain centrifugal force to produce a high pressure, medium discharge device from the discharge port (outlet). Multi-stage centrifugal pump is the same function of two or more pumps together, the fluid channel structure, the performance of the first stage of the media pressure port and the second level of the import phase, the second level of the media pressure And the third level of the import of the same, so the formation of a multi-stage series of centrifugal pump. The significance of multistage centrifugal pumps is to increase the set pressure.
    DL vertical multi-stage centrifugal pump in the daily use of the process should pay attention to maintaining the use of centrifugal pump products in order to extend its life, the equipment is not prone to failure phenomenon, DL vertical multi-stage centrifugal pump routine maintenance should be done The following points:
    1, should always wipe the centrifugal pump unit and centrifugal pump pipe above the liquid and dust or other dirt, so that the centrifugal pump to keep clean.
    2, should also be regularly replaced centrifugal pump inside the bearing grease, for example, all horizontal centrifugal pump products are usually equipped with sliding bearings, all equipped with sliding bearings centrifugal pump products in use after about 100 hours, Should be replaced with lubricants, after each run 300-500 hours after a rolling bearing for the oil.
    3, if it is sealed single-stage single-suction centrifugal pump products to be checked at any time and adjust the tightness of the filler.
    4, often check and fasten the loose bolts and nuts.
    5, often cleared out of the pool inside the suspended matter, so that the centrifugal pump into the pool clean, to prevent debris blocked the inlet pipe and was sucked into the pump after the damage to the impeller or plug in the pump inside.

2017年3月15日星期三

What is the market sales of home-type vertical multi-stage pumps?

What is the market sales of home-type vertical multi-stage pumps?
For home-based vertical multi-stage pump market sales survey process, will find that in fact the sales of this product, or very good. Although we live in many urban areas, people found themselves in the district after the purchase, it seems that there will not be enough water pressure situation. But in many mountain areas, because they are in the residential construction, may not be in accordance with the district to plan. Then their living water, often there will be enough water pressure situation. So they have to use the multi-stage pump. So its market demand, or relatively large.

Not to mention this kind of home-based products, he was selling, in fact, the price is not particularly expensive. General ordinary model of product prices, may be in the 500 to 700 dollars or so. So most of the family to buy him, this price can still be accepted.
In addition, we buy the product which will find a lot of well-known enterprises for the production of pumps, but also on this home-class multi-stage pump to sell. Although its sales price is not particularly high, but it is still a considerable profit inside. So in the sale of him, because there is no need to provide on-site installation services. So the market for such products, the relative will be more relaxed.

2017年3月13日星期一

Selection of Single - stage Single - suction Vertical Centrifugal Pump and Its Product Introduction

Centrifugal pumps are one of the most widely used pumps in industrial pumps and are now widely used in municipal, chemical, printing and dyeing, pharmaceutical, shipbuilding, foundry, food and other industries. In order to increase everyone's understanding of centrifugal pumps, centrifugal pump manufacturers today to detail the single-stage single-suction vertical centrifugal pump selection and product features introduced
SYL single stage single suction vertical centrifugal pump
SYL single-stage single-suction vertical centrifugal pump is the Shanghai Weihu pump using IS-type centrifugal pump performance parameters and vertical pump structure, in strict accordance with international standards ISO 2858 and the latest national standard design of efficient energy efficient products, IS-type horizontal pump, DL-type pumps and other conventional products of the new vertical centrifugal pump. Flow range of 1.5 ~ 2400m3 / h, head range of 8 ~ 150m, sub-basic type, expansion type, A, B, C cutting type more than 250 kinds of specifications. SYR type chemical pump, SYY (YG) type oil pump and SYHY type vertical explosion-proof chemical pump series are designed and manufactured according to the different flow medium and temperature.
Single - stage single - suction vertical centrifugal pump product characteristics
1, pump structure is compact, small size, beautiful appearance. The vertical structure of the center of gravity is lower and the center of gravity coincides with the center of the pump, enhanced pump operation stability and life.
2, easy to install. The same diameter and the same center line, the same as the valve can be installed directly in any part of the pipeline. The motor with rain cover can be used outdoors. The pump has a mounting foot so that the pump is stable.
3, running smoothly, low noise, high component concentricity. Motor with low noise bearings, and equipped with non-stop refueling device, pump impeller with excellent dynamic and static balance, running without vibration, improve the use of the environment.
4, no leakage. Shaft seal with corrosion-resistant carbide mechanical seal to solve the centrifugal pump packing seal leakage problems, to extend the service life, to ensure that the clean and clean operation of the site.
5, easy maintenance. Do not remove the pipe, as long as the removal of the pump nut, remove the motor and transmission components can be maintenance.
6, according to the site conditions of use, the pump can be vertical, horizontal, multi-way installation, according to the flow head requirements, and use, in series method to increase the required flow head.
Single - stage centrifugal pump selection requirements
1, the pump system of high working pressure ≤ 1.6MPa, the pump inlet, pump system, the amount of high working pressure ≤ 1.6MPa, that is, pump inlet pressure + pump head ≤ 1.6MPa, please specify the system when the work pressure. When the inlet pressure is greater than 0.4MPa, or the pump system working pressure is greater than 1.6MPa, should be made in the order, so that in the manufacture, the pump part of the flow and the connection part of the cast steel material.
2, the applicable medium: water pump media should be no corrosive liquid, medium solid insoluble, the volume does not exceed 0.1% of the volume, particle size <0.2Mm, such as the media with a small particle, please specify when ordering.
3, the ambient temperature does not exceed 40 ℃, relative humidity does not exceed 95%.
Our website:www.pump-weihu.com,Email:fay@welpump.com.

2017年3月8日星期三

Multi-stage pump system components

The multi-stage pump consists of five stages, one grade and four secondary, and its components include: stator, rotor, balancing mechanism, shaft end sealing mechanism, sliding pin, bearing and sliding pin system. Weihu multistage pump manufacturers to learn more about these components
1 stator part
Mainly by the bearing, the first cover, the water section, guide vane, the water section, tail cover and other parts with tightening bolts connected to the inlet section of the suction port, the water outlet are vertical upward, , The middle section, the water section of the static sealing surface is by the metal surface plus "o" -shaped seal, in the disassembly of the pump, the sealing surface must be carefully protected, guide vane cover and the middle of the sealing surface with anti- Vane at the three copper nails in the tightening of the bolt when compressed 0.6 to 0.8 mm to ensure.
2 rotor part
The structure of the rotor is closely related to the overall structure of the pump, the stability of the operation and the performance of the product, and the main performance is the way the impeller is mounted on the shaft. The feed pump is slid on the shaft and one is used to withstand the thrust Of the balance plate and consider the thermal expansion of the toothed pad and pressing ring, shaft end sets, rubber seal ring, casing, sleeve, lock nut and other components.
3 balance body
The multistage pump uses the balance plate steering force and the rotor is positioned in the axial direction.The stability of the working mechanism of this balancing mechanism is closely related to the reliability and service life of the product. The balancing mechanism is composed of balance plate, And other components, to 100% balance of axial force, high sensitivity, changes in working conditions automatically adjust the ability to start, stop and load changes will cause the balance plate and balance sets of wear and tear, it should minimize the number of starts and Increase the balance plate, balance the end face hardness. In order to prevent the balance of grinding, increase the thrust bearing.
4-axis seal
Shaft end seal has become the biggest threat to long-term continuous operation of the feed pump. In order to overcome this weak link, it is necessary to consider the good cooling of the stuffing box when packing is used, and the cooling water is introduced from the top cover and the tail cover. Cover, tail cover with heat sink, cooling water for the ambient temperature of industrial water or tap water pressure of 0.1MPa or more, the water temperature does not exceed 33 ℃, the water temperature difference of not more than 10 ℃.
5 bearing part
The bearing is directly related to the safe operation of the pump one of the key components, therefore, its structure must be safe and reliable.The pump rotor is located in the bearing body of the two sliding bearings to support the bearing with thin oil lubrication when running for a period of time bearing , The lower part of the bearing body can be used to adjust the adjustment screw, so that the rotor is always in the center position, each adjustment of the adjustment screw, the bearing body and the first cover, tail cover should be re-positioning of the positioning pin hole positioning.
6 sliding system
The feet of the sections of the multi-stage pump are supported on the table surface. The four feet of the inlet and outlet sections are fixed by the four bolts to ensure that the concentrations of the sections are maintained at the same time. Point in the pump inlet side, multi-stage pump plate and the entrance section at the foot with a cross pin, the lower part of the vertical pin to ensure that the multi-stage pump along the longitudinal side of the export side of the free expansion of the export section of the lower part of the longitudinal pin, Vertical centerline expansion.
After reading the above description, we are not more understanding of multi-level pump it? Shanghai sewage pump, Jinan pipeline pump, Boshan multi-stage pump is my company's main products, welcome friends from all walks of life come to my company purchase!

Multi-stage pump in series, parallel use

In order to meet the needs of the conditions, under certain conditions, the multi-stage pump in series or parallel is a commonly used method, then you know how multi-stage pump, parallel use of the specific situation? Multistage pump string, What are the precautions when working in parallel? With this question, let's take a look at the following.
1, two multi-stage pump in series when the total head of the work is less than twice the pump work alone, more than the series before the separate run of the head; colleagues in series after the flow than a pump work alone, this is because the pump After the series, although its lift doubled, but the pipeline resistance loss did not multiply, so the multi-stage pump rich head to increase the flow.
2, two multi-stage pump parallel flow is equal to the sum of the pump flow in parallel, but less than twice the parallel flow of the pump; colleagues in parallel with the head when the pump is greater than the work of a single pump head. More friction losses increase with increasing flow, which requires each pump to increase its head to overcome this increased pipeline loss.
Multi-stage pump string, parallel work Note:
1, multi-stage pump in series, can improve the head, but pay attention to more than one pump in series behind the pump pump strength.
2, centrifugal pump parallel operation can increase the flow, in the same pipeline system, the proportion of increased flow will increase with the number of parallel pump to reduce.
3, the best use of the same performance of the centrifugal pump for string, parallel.
4, whether it is in series or parallel work, a single centrifugal pump operating point should strive to fall within the efficient area.
After reading the introduction of Xiaobian above, we are not more understanding of the multi-stage pump? Multistage pump is my company's main products, welcome friends from all walks of life come to my company to buy, look forward to working with you!

pipeline pump installation

Mention the pipeline pump, we may not unfamiliar, and now a lot of places can be applied to the pipeline pump, which we know how to install the pipeline pump? Shanghai Weihu pipeline pump manufacturers to introduce the specific content
1, the installation should be selected away from the transport of the nearest place, so that the Jinan pipeline installed in the minimum suction height and the shortest suction pipe
Note: should ensure that the unit and the surrounding obstacles more than 150 mm distance, so that the motor fan has access to adequate air source.
2, when the pump used in the more stringent requirements of the vibration, you can use the shock absorber (pad), according to the manufacturer's instructions to install.
3, the installation of the pipeline should be reliable fixed, close to the pump flange pipe support should be sufficient rigidity, not to allow the pump to withstand the weight of the pipeline pressure.
4, Jinan pipeline pump group should be installed to avoid direct sunlight and rain.
5, Weihu pipeline pump inlet should be installed vacuum pressure gauge, the export flange should be installed pressure gauge to observe and control the operation of the pump. Pressure gauge should be the actual range of 2 to 3 times the appropriate pressure.
6, Weihu pipeline pump inlet and outlet piping should be installed gate valve to facilitate maintenance and operation regulation.
7, wiring: must be required by the nameplate correct wiring, wiring, the terminal must be strong, do not allow loose, otherwise, will cause poor contact caused by phase loss burner.In order to ensure reliable operation of the motor, electrical switch should be installed overload Protection device, and according to the motor nameplate on the current requirements to adjust the size of the protection device settings.
Warning: If the overload protection device is not installed, it will cause the motor to burn out due to the sudden increase of the current when the outlet valve is fully open or when the large flow is running or under certain circumstances.
8, in the inhalation state (water level below the impeller axis or water level below the pump inlet axis), the standard atmospheric pressure, the pump installation height H = 10- (NPSH) r-0.5-hw, hw for the suction pipe resistance Loss (formula in the calculation unit: m).
9, in order to facilitate the start before the Jinan pipeline pump irrigation, can be added at both ends of the check valve by a bypass valve, before the pump starts to open the bypass valve to the pump irrigation, filled and closed, easy to use. In the high-rise building water supply or outlet pressure greater than 0.2MPa pump, in addition to the discharge port with a gate valve, but also between the pump outlet and gate valve with a check valve, so as to avoid sudden power failure caused by high pressure water impeller damage.
After reading the above description, we know how to install Jinan pipeline pump? Later Xiaobian will continue to release some of the relevant contents of the pipeline pump, welcome to the pump pump interested friends continue to our website.

2017年2月16日星期四

Centrifugal pump start method

Centrifugal pump start method, centrifugal pump start note
  Before the start of the centrifugal pump is ready, open the diversion gate, so that the front tank to the design level, you can start the pump.
Centrifugal pump start Note:
When starting the centrifugal pump, the staff will have to leave the unit at a certain distance. For centrifugal pumps and volute mixed flow pump, usually closed valve start, standby group speed reaches the rated value, you can open the vacuum gauge and the pressure gauge on the valve, this time, the pressure gauge reading should rise to the pump flow is zero When the maximum value, then you can gradually open the pressure on the pipeline valve. If there is no exception, then the vacuum gauge reading will gradually increase, the pressure gauge reading should be gradually decreased, the motor ammeter reading should be gradually increased. Start the work until the valve is fully open, that is completed. In the closed valve should be noted that the valve running time should generally not exceed 5 minutes, such as the time is too long, the pump liquid heat, may cause accidents.
  For self-priming pumps, vertical axial flow pump and guide vane mixed flow pump, usually open the valve. While filling the rubber bearing, while the motor can start, until the speed reaches the rated value, stop filling water, that is, to complete the start work.

Demolition of Double - suction Centrifugal Pump

Double suction pump disassembly method, centrifugal pump disassembly method
Remove the double suction centrifugal pump do not need to break into the outlet pipe and motor, as long as the pump cover can be opened.
(1) Removal of the centrifugal pump pump cover
    First loosen the packing glands at both ends of the pump cover, pull the packing glands on both sides, then release the nuts on the pump cover and remove the centrifugal pump cover.
(2) disassembly of centrifugal pump coupling
    Coupling disassembly can be carried out before and after removal of the pump cover.
(3) Removal of the centrifugal pump rotor
Remove the bearings at both ends of the pump shaft and the bearing cap at both ends, remove the two bearing bodies, and release the two round nuts pressed against the bearing with a special tool. With a pull bearing at both ends of the rolling bearing. After removing the rolling bearing, remove the bearing cover, retaining ring, packing gland, water seal ring, packing sleeve and other parts from the pump shaft, and then remove the sleeve. Finally press the impeller with a press. If there is no press, you can put the impeller flat pad, with a wooden hammer to the impeller back.

2017年2月15日星期三

How does single-stage single-suction centrifugal pumps work?

Single-stage single-suction centrifugal pump from the impeller, pump shaft, pump and other components. Impeller center facing the inlet, water, water pipes, respectively, and centrifugal pump water, outlet connection.
How does the centrifugal pump work: the water centrifugal pump should be filled with water before starting. When the power machine through the pump shaft to drive the high-speed rotation of the impeller, the impeller in the water due to the role of inertial centrifugal force, from the impeller center to the outer edge of the impeller, and pooled into the pump body, the potential energy and kinetic energy in the pump body was directed to the outlet , Along the water pipeline to the outlet. At the same time, the impeller inlet to produce a vacuum, and the role of the water in the inlet basin pressure for the atmospheric pressure, the water in the pool will be under the pressure difference between the role, through the inlet pipe into the impeller. Impeller kept spinning, the water is constantly being thrown and inhaled, centrifugal pump is the work of this.

The main advantages and disadvantages of centrifugal pumps

The main advantages of centrifugal pumps
  A. Centrifugal pump flow range is very large, commonly used in the 5 ~ 2000m. / H, the largest foreign reach 54500m3 / h. Another flow and pressure are smooth, no fluctuations.
    B. Centrifugal pump speed is high, can be directly connected with the motor and steam turbine, transmission mechanism is simple and compact.
    C. Easy to operate, easy to adjust and repair, and easy to automate and remote operation.
    D. Centrifugal pump compared with the same indicators of the reciprocating pump, the structure is simple and compact, small size, light weight, fewer parts, easy manufacturing, low cost, and small footprint, so its equipment and repair costs are relatively low.
  Centrifugal pumps have major drawbacks:
A, in general, the centrifugal pump before starting the first pump or water ring vacuum pump to pump out the air. Self-priming centrifugal pump before the start, although there is no need to pump, but there are limitations on the use. B, liquid viscosity on the performance of a greater impact on the pump. When the liquid viscosity increases, the pump flow, head, suction and efficiency will be significantly reduced. C, centrifugal pump in the case of small flow of high-lift applications, subject to certain restrictions. Because the small centrifugal pump pump flow channel is very narrow, manufacturing difficulties, while the efficiency is very low. Although the centrifugal pump has some shortcomings, but the advantages of more, in many cases, centrifugal pumps are replaced by the reciprocating pump, so the centrifugal pump has been widely used.

What is the reason for the centrifugal pump trip

In general, the main reasons for the pump trip are: (1), the use of centrifugal pump head less than the head of the pump too much lead to excessive flow after the current rise and over current, the solution control the outlet valve opening flow control and the current Down to allow the current range, or change the impeller diameter to reduce the pump head. (2), the pump motor damps lead to excessive current. (3), pump motor quality problems. (4), the pump voltage is unstable. (5), pump control cabinet system problems.
1: centrifugal pump trip fault phenomenon
    After the unit has been put into operation, the centrifugal pump will work for a period of time after a closing trip. After excluding the switch mechanism failure, according to the conventional method to check the cable, the secondary circuit wiring and the relay and its settings are normal, start again and often successful. After the suspected dcs system caused by a soft fault, but changed in the control panel operation, this phenomenon will still occur.
2: Centrifuge the cause of the pump trip
In order to find out the cause of this phenomenon, observe the change of the meter in the process of closing the switch to confirm what causes it to trip.
Test which the voltmeter monitor microcomputer trip circuit, mA table monitor differential relay 1cj, 2cj action, ammeter monitoring thermal protection circuit. After a good meter, start the pump, after a period of time test, and finally once a pump to start the trip, while observing the milliphe pointer deflection of the pointer, the other monitoring table does not respond, the new put on xjl -0025/31-type integrated block signal relay 1xj also action out of the card, indicating that the differential protection action caused by tripping.
3: Centrifugal Pump Trip Root Cause Analysis
     Differential protection action, first suspected of being protected within the equipment failure. Through routine inspection, centrifugal pump motor and its cable normal, differential relay calibration is normal, the current transformer polarity connection is correct. After troubleshooting the cause of the equipment failure and wiring errors, the differential protection operates during the motor start, indicating that the differential current in the differential circuit exceeds the differential relay setting during this process.
     Under normal circumstances caused by differential circuit differential current causes there are two main points: First, the motor on both sides of the current transformer variable ratio error is different from the existence of a very small difference current, the current difference is less than the motor rated current id 5% The Second, the difference between the secondary load on both sides of the current transformer will also cause the difference between the variable ratio, so there is a differential current. The difference between the current transformer load in the differential protection circuit of the feed pump motor is only about 50 m in the length of the secondary cable, and the power consumption of the differential relay is not more than 3 va at the rated current, and the secondary load is not weight. Inspection found that the pump head motor differential protection with the first and second side of the current transformer models are lmzbj-10, b class 15 times the rated current, variable ratio 600/5, capacity 40 va, fully meet the secondary load requirements.
  The above analysis is based on the normal operation of the conditions, the motor starts, the situation is different. Motor current is very large start, both ends of the current transformer may be saturated, this time due to the current transformer magnetization characteristics are inconsistent, the secondary difference current may be great. According to the sub-relay factory lcd-12 differential relay set instructions, the relay action current setting value izd = △ i1 × kk × in / n = 0.06 × 3 × 356/120 = 0.534a (where: △ i1- First and the end of the current transformer normal operation of the maximum error, 0.04 ~ 0.06; kk-reliable coefficient, 2 ~ 3; in-motor rated current; n-current transformer ratio). Should be set at 1.0a position. In the case of the use of b-class transformer, the differential relay operating current is set at 1.5a and the braking coefficient is 0.4, the differential protection is occasionally operated at the time of starting the motor due to the saturation characteristic of the b-type current transformer Lower, low resistance to saturation, can not meet the requirements of differential relays. Usually require differential protection circuit current transformer using d-class, d-class transformer saturation point higher, not so easy to saturation, can reduce the motor when the differential flow through the differential circuit current. In the replacement of the d-level current transformer, while the differential relay operating current set at 1.0a, the braking coefficient of 0.4, there has been no switch off the trip that is the fault.

2017年2月14日星期二

ISG pipe pump whether there is suction

ISG pipeline pump is installed in the pipeline on an increase in the pump, is also a kind of centrifugal pump, usually in the pipeline water but the pressure is not enough to transport water to a higher destination, the use of ISG pipeline The pump is pressurized to reach the destination.
Is the ISG pipeline pump sucking?
Of course, but please do not misunderstand the two concepts of suction and self-absorption.
Self-priming refers to the process of pumping water from the lower to the pump chamber in the absence of water (empty tube) in the inlet line (the verb, self-absorption is an action and a process), only the self-priming pump Only with self-absorption function.
Suction - refers to the distance in the inlet pipe, but the import without positive pressure, the pump in the work of its imports can absorb much depth within the distance (quantifier, in length). All centrifugal pumps actually have suction, but the length of different, in short, the higher head, suction will be correspondingly higher, but no specific conversion standards. In general, the suction line of the ISG pipeline pump is not more than 4 meters without preconditioning without any auxiliary equipment.
After installing the siphon device, the ISG pipeline pump can actually operate as a self-priming pump, giving the self-priming capability of the ISG pipeline pump by integrating the siphon. But there is self-absorption pump, who will be so superfluous it

The basic principle of ISG pipeline pump

ISG pipeline pump for the vertical structure, import and export caliber the same, and is located in a unified center line, like the valve can be installed in the same pipe, compact appearance, small footprint, low construction investment, such as with a protective cover Can be placed outdoors.
ISG pipeline pump impeller directly on the motor's elongated shaft, axial size is short, compact, pump and motor bearing configuration is reasonable, can effectively balance the pump running radial and axial load, thus ensuring the pump running smoothly , Vibration noise is very low.
ISG pipe pump shaft seal using mechanical seal or mechanical seal combination, the use of imported titanium seal ring, medium high temperature mechanical seal and the use of carbide material, wear-resistant seal, can effectively increase the mechanical seal life.
ISG pipeline pump installation easy maintenance, no need to dismantle the pipeline system, as long as the removal of the pump seat nut can take out all the rotor parts.
ISG pipeline pump can be used according to the requirements of the flow and head of the need to use the pump string, parallel operation.
ISG pipeline pump can be used in accordance with the requirements of the pipeline layout of the pump vertical and horizontal installation.
ISG pipeline pump works: the pump is filled with liquid in the case, the impeller rotation produces centrifugal force, the impeller channel in the centrifugal force of the liquid thrown to the periphery, into the pump shell, the impeller center to form a vacuum, the liquid in the atmosphere Under the action of pressure, by the import pipeline into the impeller. So that the liquid is constantly being sucked and hit. The liquid that gets energy in the impeller has a large kinetic energy when it flows out of the impeller, which is collected in the helical pump housing and becomes kinetic energy in the later diffuser.

Trouble Cause and Treatment of Centrifugal Pump

In the water supply system, the pump is in regular operation, often due to various failures so that the pump can not work properly. Centrifugal pump common faults, the causes and treatment methods:
Water pump is not on the water
(1) When the pump suction pipe due to the slope of the tube there is air and has formed a gas plug, so that the pump can not continue to absorb water caused by water pump. When there is inverted slope, should adjust the slope, and timely rejection of the pump and the suction pipe of the air.
(2) lack of water at the end of the valve or damage, so that the water pipe is less than water, or the end of the valve and the suction port is blocked by debris, so that the end of the valve closed lax. When the above-mentioned fault should be confirmed after the timely cleaning of dirt, maintenance of the end of the valve, should be replaced when damaged.
(3) Bottom valve submerged depth is not enough to cause the pump is not on the water, should increase the depth of the suction pipe immersed in the water.
(4) the pool (water tank) in the water level is too low will make the pump is not on the water, this time should check the water system in the water, water pressure is seriously inadequate; float valve, liquid level control valve is fault. Should be timely adjust the replenishment time (such as the use of low water at night when the water), repair or replacement of the failure of the inlet valve.
2. Pump water discharge in addition to check the submerged depth of the suction pipe, suction pipe down the gas and other reasons, but also need to check the pump impeller seal ring is damaged and timely replacement.
3. Water pump bearing overheating In the pump operation, the bearing temperature should not exceed 60 ℃, when the bearing lack of oil or pump and motor shaft is not the heart, bearing clearance is too small, the packing pressure too tight, can cause the bearing overheating. At this point, should adjust the concentricity, refueling, adjust the packing gland tightness.
4. Pump running vibration and noise is too large.
Water pump concentricity deviation is too large will produce greater vibration, followed by check the anchor bolts, the base bolts are tightened without loosening. Noise reduction or vibration isolation devices shall be added to buildings requiring strict control of noise and vibration.
When the suction pipe depth is too large, the water level is too low, but also make the pump cavitation phenomenon and increase the pump noise.

Assembly method of centrifugal pump impeller

Centrifugal pump impeller bore and journal between the gap with the gap between the value of 0.1 ~ 0.15 mm. When the impeller is to be fitted, the impeller shall be slid on the journal without swinging. When the gap is too small, you can use the file cutting method to reduce the size of the shaft diameter, but also in the lathe on the impeller of the hole car larger, in order to ensure that the gap should be. When the gap is too large, replace the new impeller so that the clearance accuracy is not affected by the clearance.
When assembling the centrifugal pump impeller to the shoulder, the M should be facing the pump body out of the M pipe, should not produce axial displacement. No friction between the impeller back and the pump body, but the axial gap between them can not be too large. If the axial clearance is large here, the amount of leakage of the axial seal is increased. In order to reduce the axial clearance here, the thickness of the gasket on the front and rear axle cover can be readjusted, that is, the thickness of the gasket of the front bearing of the pump to the M side is thinned and will be close to the coupling The thickness of the rear bearing gland is thickened. In adjusting the thickness of the bearing gland gasket, the total weight of the front and rear bearing glands should be equal to the total thickness of the original assembly, ie the thickness of the front bearing gland pad minus the thickness of the rear bearing gland pad To be equal. While adjusting the gasket, tap the pump shaft slightly rearward to move it a very small distance, and then press the rear cover, thus reducing the axial clearance between the impeller's back and the pump The If the back of the impeller and the pump body is too small between the friction between the friction, the adjustment of the gasket is the same as above, but the rear bearing gland pad thinner, the front bearing gland pad thickening, and the pump shaft Move forward a little distance can be.

2017年2月13日星期一

How to carry out the maintenance of vertical multi-stage centrifugal pump

Maintenance method for vertical multi-stage centrifugal pump:  

1.  Vertical multistage centrifugal pump repair, motor control switch must be in the "off" position and hanging tablets so as not to cause physical damage. In multistage pump disassembly should be in the parts together mark, for the installation can be carried out smoothly; multistage pump to remove the small parts and fasteners with box installed, mark, indicate the premises; multistage pump removed parts clean, coated with anti rust oil, paint surface if there is corrosion, to the eradication of the corrosion and repainted; horizontal multistage centrifugal pump "O" shape ring, a packing and corrosion of fastening pieces can not be reused for the parts.  
2. The vertical multistage centrifugal pump maintenance, the first pump have been removed from the tank, dismantling the motor and a machine base, remove the lower pump shell, knock down the shaft and impeller (pay attention to the pump shaft anticorrosion coating) release bearing sit six hexagon bolt, then is a pump shaft and a bearing assembly together can be pulled out for maintenance.  

3. Rotating coupling and just down into the belt, vertical multistage centrifugal pump maintenance and replacement of wearing parts after re assembly, the bearing seat, a bearing installed in the pump shaft upper part of the sealed bearing cover installed coupling and tight and round nut, correction of pump shaft bending, the bearing of the pump in the pump body and the bearing seat is arranged in the middle seat, adjustable impeller and pump shell gap, the impeller and the shaft and impeller cap together with phenolic mastic dip in the pump shaft, such as phenolic mastic fully cured, the pump cover installed and assembled by hand in a pump shaft is normal. Such as the replacement of bearings and pump shaft, the first to open the pump shaft and the shaft coupling, loosen the upper and lower bearing cover 12 screws, the bearing can be made up to play.  
4. In the maintenance of vertical multi-stage centrifugal pump for two periods, one is running, one is when the.  
 1). The operation of the multi-stage pump multistage pump packing leakage; multistage pump lubrication pressure; multistage pump lubricating oil level and bearing temperature; do a good job running log, such as horizontal multistage centrifugal pump fault should be recorded in detail.  
2). Multi-stage pump stop. Replace the old vertical multistage centrifugal pump packing; replacement of vertical multistage centrifugal pump oil (pump thrust bearing box); monthly water to flush the vertical multistage centrifugal pump water guided bearings, time is about 2 minutes; at the same time, turn the pump rotor; check run horizontal multistage centrifugal pump water skiing system, check whether the loosening of the fastener.  

Cause and treatment method of high current of centrifugal pump

Cause and treatment method of high current of centrifugal pump

1. Process medium relative density and viscosity index:  

 Processing method: check the material component to make its viscosity and relative density and design value is in line with the process operator to adjust  

2. Electrical failure  :

 Processing method: check the circuit breaker heater setting value, check the voltage, three-phase current should be balanced, the error is not greater than 3%  

3. When the pump starts, the outlet valve is open, the resistance in the outlet pipe is too small :

Processing method: the outlet valve is closed, the pump starts slowly open the outlet valve .

4. Balance tube is not smooth : 

Processing method: clear the balance tube  

5. Pump assembly is not good, static and dynamic part of the friction or stuck : 

Treatment method: to pump the assembly, check the fit clearance, bearing clearance, mechanical seal, and so on, and strictly according to the design requirements to adjust .

2017年2月10日星期五

Series and parallel operation of centrifugal pump

Centrifugal pump in addition to a single independent work, but also can be a few pumps in parallel or in series. Parallel operation of the pump, that is, the inlet and outlet of several pumps are respectively connected in the same suction and discharge piping system. But parallel pump as far as possible not to use the same suction tube, so as not to interfere with each other. Series is the 1 sets of centrifugal pump discharge port received second sets of centrifugal pump suction inlet pipe line.  
1. Centrifugal pump parallel operation can increase the flow rate. In the same pipeline system, increased traffic ratio decreases with the increase of the number of parallel pumps.  
2. Centrifugal pump in series can improve the head, but to pay attention to the pump in series in tandem pump body strength.  
3. It is best to use the same performance of the centrifugal pump in series and parallel.  
4. Either in parallel or in series, the working point of the single centrifugal pump should be in the high efficiency zone.  

Method for water diversion and exhaust of centrifugal pump

Method for water diversion and exhaust of centrifugal pump
1. In the inlet and outlet valves of water filling. This method is installed in the inlet pipe of a valve, then the water pipe can be filled with water.  
2. Hand pressure pump water filling. Some pumps with a hand pump, can also purchase or do small hand pump installation must be installed in the water inlet valve. After the valve is closed, the first small amount of water filled with water for water diversion, and other hand pressure pump water, said the pump has been filled with water, you can start work.  
3. The use of vacuum equipment exhaust water filling. Centrifugal pump and vacuum pump exhaust gas is the same reason, so the use of water ring vacuum pump exhaust to reach the role of water filling.  

What are the characteristics of corrosion resistant chemical centrifugal pump

1.  Corrosion resistance, high temperature resistance, low temperature: chemical pump delivery of the media, including chemical raw materials, reaction intermediates, such as the general is a corrosive medium. The materials of pump selection of an appropriate and reasonable, with corrosion resistance; and the chemical pump for transporting the media sometimes is medium high temperature, flow of liquid material, the reaction required and the resulting heat carrier liquid. For example: condensate pump, boiler feed pump, heat pump. Chemical pump delivery of low temperature medium, there are many kinds, such as liquid oxygen, liquid nitrogen, methane and other, the pump temperature work mostly in a 20 - 10 DEG C. No matter transport resistance to corrosion, high temperature or low temperature chemical pump, material selection and structure must be appropriate, must have sufficient strength, design and manufacture of pump parts to thermal shock, thermal expansion and low temperature deformation, the influence of cold brittleness. To ensure that the pump can be safe and stable operation.  
 
 2. To meet the needs of chemical process: Pump in chemical production, not only to transport liquid materials and requirements of the process to provide the necessary pressure, must also ensure the delivery amount of material, in certain chemical unit operation, pump flow and head to stabilize, maintain a high efficiency and reliable operation of the pump.  
 
3. Resistance to abrasion and erosion: contains solid particles suspended in the chemical pump delivery of logistics, while the pump impeller chamber while others work under high pressure and high flow rate, pump parts surface protection layer is destroyed, its life is short, so must improve the chemical pump wear resistance, erosion resistance, which requires materials of pump selection of wear resistant steel, ceramics, cast iron, and so on, the choice of erosion resistant titanium, manganese.  
 
4 . No leakage or less leakage: flammable, explosive, poisonous and harmful liquid chemical pump delivery of most of the media, once the leak will seriously pollute the environment, endanger the personal safety and worker's physical and mental health, but do not meet the factory and clean and civilized factory without leakage, which must ensure operation of chemical pump does not leak, in pump seal on the new technology, new material, according to the operating rules and high quality maintenance.  
 
5.  Reliable operation: the operation of the chemical centrifugal pump is reliable, including two meanings: first, the long period of operation is not a failure; the two is running in a variety of parameters. The reliability of operation is very important to the chemical production. If the pump often fails, it will not only result in regular production, affect production and economic benefits, and sometimes may cause accidents in chemical systems. Chemical pump speed fluctuations will cause fluctuations in flow and pump outlet pressure, so the chemical production can not normal or system reaction affected, the material can not balance, not only wasteful, and even cause decline in the quality of the products or the rejection of the products. So the chemical pump has the characteristic that must run smoothly and reliably.  
 

2017年2月9日星期四

Selection of Start Mode of Centrifugal Pump Control

Centrifugal pump used in the cage motor configuration centrifugal pump control cabinet has a high starting current when starting.
    Motor power is less than 4kW, the centrifugal pump control cabinet starting mode using a direct closing circuit and soft starter. Motor power is greater than 4kW, the centrifugal pump control cabinet priority to use the star delta connection method, starting transformer, soft starter and inverter with the starting operation mode.
    Centrifugal pump control cabinet in the direct closing of the circuit, the motor winding end of the wrong connection into a triangular connection, so that the motor starts
The torque required to ensure mechanical rotation is instantaneously obtained. The complete unit will soon reach the normal operating speed.
    For motors. This turn-on method is most advantageous even when the starting current is increased to eight times the rated current. Because of the large capacity of the motor, this method will close the grid load soared, resulting in interference around the device voltage disturbance phenomenon wins, so the use of public low-voltage power grid (400V). Should be strictly abided by the power supply industry on the power is greater than 5.5kW when the direct operation of the provisions.

How to Measure the Speed of Centrifugal Pump

How to measure the Centrifugal pump speed, how to measure the pump speed
The speed measurement can be used to determine the rotational speed of the object. A different method can be used to measure the pump speed.
     So how to measure the Centrifugal pump speed?
     1, magnetic induction speed sensor. The magnetic field lines through the sensor coil change, during sensing
     The periodic voltage is generated in the coil. The voltage process is counted. Measured the speed of the pump.
     2, manual vortex tachometer with the end of the shaft or motor shaft at the end of the tachometer.
     3, the electronic counter (in the high precision when used). The pulse signal proportional to the pump speed can be transmitted from the pump shaft of the centrifugal pump to the counter without contact (flash method or magnetic method).
     4, slip meter (slip coil or magnetic needle). Install at a distance from the motor at a certain distance.

Power calculation formula of centrifugal pump

The characteristic curve of centrifugal pump is the inherent characteristic of the pump, it has nothing to do with the use of the outside world. However, once the pump is arranged in a certain pipeline system, the actual work is not only related to the characteristics of the centrifugal pump itself, but also depends on the working characteristics of the pipeline. Therefore, to select and make good use of centrifugal pump, it is also considered the characteristics of the pipeline at the same time. 
Because there are various losses in the operation of the centrifugal pump, the effective pressure head and flow rate of the pump are lower than the theoretical value, and the input pump power is higher than the theoretical value. 
H______ pump effective pressure head, that is, the unit volume of liquid in the gravity field from the pump to get the energy, m; 
Q ______ the actual flow ofpump, m3/s; 
P ______ liquid density, kg/ m3; 
Ne______ the effective power of the pump, that is, the mechanical energy of the liquid from the pump unit at the time of the unit, W. 
Effective power can be written as Ne = QH = g 
The power of the centrifugal pump is referred to as the pump shaft power, which is expressed by N. The effective power and shaft power is defined as the ratio of the total pump efficiency, namely =Ne/N according to the above analysis, we can understand the energy loss in the centrifugal pump to work, how to improve the power of centrifugal pump for efficient use of products of great significance. Each product has a shortage of places, these weaknesses may lead to a reduction in the use of the product performance. At this time the power is a very good test method, how to maximize the power of the product, the need for professionals to do more work and research. 

Reasons for the poor rotation of multi-stage centrifugal pumps

1.Multistage centrifugal pump parts with under magnetized. Before the assembly of all parts shall be demagnetization. 
2.Multi stage centrifugal pump and engine shaft coupling. The coaxial degree should be guaranteed within 0.1mm. 
3.Needle sleeve unqualified or needle breakage. Repair or replace. 
4.Multi-stage centrifugal pump working oil output is blocked. Removal of foreign body. 
5.Pump axial clearance or radial clearance is too small. Readjust repair. 
6.Multi-stage centrifugal pump with dirt. Disintegration to remove foreign body. 
7.Assembly error. The processing base of multistage centrifugal pump two pin hole surface is not the assembly datum, such as the pin into the first, then tighten the screws, the pump will not turn. The correct method is, while rotating the multistage centrifugal pump side screw, finally drilled pin holes and into the pin. 

Application of packing seal in multi-stage pump

Application of packing seal in multi-stage pump
1.There is a certain plastic, under the effect of the compression force can produce a certain radial force and contact with the close shaft. 
2.There is enough chemical stability, non polluting media, the filler is not the medium foam expansion, filler in the impregnation agent is not dissolved, the filler itself is not corrosive sealing surface. 
 
3.Filler self lubrication performance is good, wear resistance, friction coefficient is small. 
 
4.There is a small amount of axis offset, the filler should have enough flexibility. 
 
5. Simple manufacture, convenient filling 
 
To this end, often need to fill the compression level to adjust, after packing the lubricant in the running for a period of time has been lost, and then squeezed out some lubricant, pressing force relaxation while compensating for volume changes caused by filling. Of course, such a regular squeeze filler, and finally will make the dipping agent depleted, so the regular replacement of filler is necessary. In addition, in order to maintain the liquid film and take away the friction heat, to allow a small amount of leakage is also necessary. 

2017年2月7日星期二

The difference between multi - stage centrifugal pump and single - stage centrifugal pump

The difference between multi-stage pump and single-stage pump
  As a wide range of centrifugal pump products in the selection of multi-stage centrifugal pump and single-stage centrifugal pump can sometimes meet the same parameters, the user does not know when to choose the product of choice which series of products, but do not know the multi- Centrifugal pump and single-stage centrifugal pump where the difference.
The difference between multi-stage pump and single-stage pump is mainly multi-stage centrifugal pump used in two or more than two impeller is called multi-stage centrifugal pump, and single-stage centrifugal pump is only one impeller so called single-stage centrifugal pump. Multi-stage centrifugal pump if the use of multiple impeller in the top of an impeller will be more than one level of lift, the main feature is the high-lift, and single-stage centrifugal pump in the lift can not reach the effect of multi-stage centrifugal pump, Building water supply or high-level fire with water are multi-stage centrifugal pump products, single-stage centrifugal pump is generally used for factory or low-pressure booster water use.
The difference between multi-stage pump and single-stage pump There are prices in the above single-stage centrifugal pump and multi-stage centrifugal pump price difference between the more obvious, included in the parameters of two types of pumps can meet the requirements of single-stage centrifugal pump than multi- Centrifugal pump price is much less, because in the manufacturing cost for single-stage centrifugal pump than multi-stage centrifugal pump manufacturing costs less. Therefore, single-stage centrifugal pump to meet the conditions of the conditions we recommend the selection of single-stage single-suction centrifugal pump is better.
Vertical multistage pump and vertical single-stage pump difference is: vertical multi-stage pump it is not suction, and vertical single-stage centrifugal pump installed after the end of the valve has a certain suction.

Single-stage double-suction centrifugal pump features and appearance structure

Single-stage double-suction centrifugal pump, single-stage double-suction centrifugal pump characteristics, single-stage double suction centrifugal pump structure
First, the characteristics of single-stage double-suction centrifugal pump
Single-stage double-suction centrifugal pump is characterized by large flow, high head; pump is open in the level, maintenance without dismantling the motor and pipeline, as long as the pump cover can be opened for inspection and maintenance; Layout, the basic impeller axial balance, so the operation is more stable; as the pump is relatively bulky, covers an area of ​​large, it is suitable for use. Single-stage double-suction centrifugal pump currently has S, Sh two series. The S series pump is a newer product of Sh series pump. Its performance index is more advanced than Sh series pump. Its scope of application is: pump inlet diameter is 150 ~ 1 400 mm, rotational speed is 360 ~ 2 900 r / min, 18 000 m3 / h, the head is 12-125 m. Widely used in hilly and mountainous areas of large-scale irrigation.
Second, single-stage double-suction centrifugal pump structure
Single-stage double-suction centrifugal pump shape shown in Figure 1-8, the single-stage double suction centrifugal pump structure shown in Figure 1-9. Its main parts and single-stage single-suction centrifugal pump is basically similar, the difference is: single-stage double-suction centrifugal pump impeller is symmetrical, as if by two identical single-suction impeller back to back together, water from Both sides into the impeller. The impeller is fixed with the key, shaft sleeve and two side sleeve nuts. The axial position of the impeller can be adjusted by the sleeve nut. The pump cover and pump body of the single stage double suction centrifugal pump together form the semi-helical suction chamber and the snail pressure Out of the room. Pump suction and outlet are cast in the pump body, was horizontal, perpendicular to the pump shaft. After the flow of water from the suction mouth, along the semi-spiral inhalation chamber from both sides into the impeller, so the pump known as single-stage double-suction centrifugal pump; pump cover and the pump body is open in the horizontal, Said single-stage double-spiral volute centrifugal pump. Single-stage double-suction centrifugal pump impeller inlet and the outer edge of the Department fitted with two leaking ring, said double suction damping ring. Double-suction pump in the pump shaft piercing the pump at both ends of the total installed with two sets of packing seal, the pump is running when the pump ring, , A small amount of high-pressure water through the pump cover in the open surface of the groove and seal ring flow into the packing room, the role of water sealing; double suction pump from the inlet direction, the right end of the shaft coupling, according to need The coupling is mounted on the left end of the shaft, and both ends of the pump shaft are supported by bearings. Bearing type generally single row radial ball bearings, when the shaft diameter and speed of the product Dn,> 300 000 rruu. R / min when the sliding bearing.

Characteristics and Model Meaning of Pipeline Centrifugal Pump

The characteristics of pipeline centrifugal pump, pipe centrifugal pump model significance
  Pipeline centrifugal pump is mainly used for pipeline water pressure to increase the occasion. Pipeline centrifugal pump It is directly connected with the pipeline, the motor is located above the pump, pump suction and outlet diameter the same, and in the same horizontal plane, the bottom of a square base, can be directly installed on the concrete foundation. Small pipe pump to be installed directly in the pipeline, the pump should be supported on both sides of the pipeline.
  Pipeline centrifugal pump is mainly characterized by high efficiency and energy saving, low vibration, low noise, simple structure, easy installation, small footprint, it can be used for conveying water, petroleum, chemical liquid. Equipped with outdoor explosion-proof motor of the pipeline pump is suitable for outdoor operation.
   Pipe centrifugal pump model meaning: for example, ISG50-125A 50 - pump suction and outlet diameter of 50mm; commonly used pipeline centrifugal pump to the letter ISG said, IRG-hot water pipeline centrifugal pump, ISGB-proof pipeline centrifugal pump, IHG- Stainless steel chemical pipeline centrifugal pump, 125-behalf of the pump impeller diameter m; A-wheel diameter after a small car.
  In addition to these types of pipeline centrifugal pump, the pipeline centrifugal pump, such as not qualified for some special occasions, we can also make other types of pipeline centrifugal pump products such as demolition of the pipeline centrifugal pump or large flow pipe centrifugal pump products for selection .

Disassembly and assembly of centrifugal pump

Centrifugal pump disassembly and assembly assembly, is to check, repair the pump when the important work. Some special type or large centrifugal pump in the factory and transport process, and sometimes need to be dismantled into parts, such as single-stage double-suction centrifugal pump open in the pump unit installed, in accordance with national standards and corporate standards It is required that the pump be assembled correctly. The overall pump factory in the manufacturer's rust-proof guarantee period, the internal parts should not be demolished, only clean appearance. When more than rust-proof period or obvious defects to be removed, the demolition, cleaning and inspection should be consistent with the provisions of the equipment technical documents. When no technical requirements, the national standard may refer to the general provisions. Disassemble the water pump, in the assembly before the pump parts seat rigorous inspection, the pump's main parts, components and ancillary equipment, in the surface and set the parts, parts of the end shall not forgive scratches and scratches; Cracks, crush and other defects. After cleansing the parts, remove the water and parts, parts and equipment should be coated with lubricating oil and the order according to the classification of heavy volume.
  Disassembly or Assembly Before assembling a centrifugal pump, various tools need to be prepared in advance, including the fitter tools (such as wrenches, hand hammers, screwdrivers) and inspection tools (such as the micrometer card, feeler) and some auxiliary, Supplies (such as bolts loose agent, lubricants, gaskets) and so on.

The Advantages of Centrifugal Pump and the Composition of Centrifugal Pump

The advantages of centrifugal pump, centrifugal pump device composition
First, the advantages of centrifugal pump
   Centrifugal pumps have many advantages over other types of pump centrifugal pumps, such as uniform flow, smooth operation, low vibration, high speed, low installation and maintenance cost, wide application range (including flow, head and adaptability to medium). Therefore, the centrifugal pump is widely used in chemical production of a chemical pump.
Second, the composition of centrifugal pump
     Centrifugal pump device is a centrifugal pump and a certain pipeline, and the valve and the composition of the delivery system
The liquid to be delivered by the centrifugal pump to supply energy, through the pipeline transportation system to a certain place. Pipeline transportation system refers to the suction pipe, discharge pipe and pipe fittings and so on.

Classification and structure characteristics of multistage pump 

Multistage pump is a pump with two or more than two impeller. Usually the structure has the spiral case type multistage pump and the sectional type multistage pump.  
 The spiral case type multistage pump is generally used in the open type structure to facilitate the maintenance, and is advantageous for the symmetrical arrangement of the impeller, and reduces the axial force on the rotor. But the structure of technology and less: Series increasing, the shape of the pump body and cover more complex, pump dimensions is large, especially level and need to configure some level between channel, the pump complex shape. And when the series more, head higher, the opening of the sealing surface is more difficult. Based on these factors, the wide application of this structure is limited.  
 Segmented multi-stage pump compact structure, is conducive to improve the degree of standardization, generalization. Because of the structure of the pump head depends on the pump series, so the head of the pump range is wider.  

Power calculation formula of centrifugal pump

The characteristic curve of centrifugal pump is the inherent characteristic of the pump, it has nothing to do with the use of the outside world. However, once the pump is arranged in a certain pipeline system, the actual work is not only related to the characteristics of the centrifugal pump itself, but also depends on the working characteristics of the pipeline. Therefore, to select and make good use of centrifugal pump, it is also considered the characteristics of the pipeline at the same time. 
Because there are various losses in the operation of the centrifugal pump, the effective pressure head and flow rate of the pump are lower than the theoretical value, and the input pump power is higher than the theoretical value. 
H______ pump effective pressure head, that is, the unit volume of liquid in the gravity field from the pump to get the energy, m; 
Q ______ the actual flow ofpump, m3/s; 
P ______ liquid density, kg/ m3; 
Ne______ the effective power of the pump, that is, the mechanical energy of the liquid from the pump unit at the time of the unit, W. 
Effective power can be written as Ne = QH = g 
The power of the centrifugal pump is referred to as the pump shaft power, which is expressed by N. The effective power and shaft power is defined as the ratio of the total pump efficiency, namely =Ne/N according to the above analysis, we can understand the energy loss in the centrifugal pump to work, how to improve the power of centrifugal pump for efficient use of products of great significance. Each product has a shortage of places, these weaknesses may lead to a reduction in the use of the product performance. At this time the power is a very good test method, how to maximize the power of the product, the need for professionals to do more work and research. 

Cause and harm of centrifugal pump cavitation

The reason of low temperature centrifugal pump cavitation: pump through the rotation of the impeller on the liquid work, so that the liquid energy increases. In the interaction process, the velocity and pressure of the liquid changes. In general, the inlet of the impeller of the centrifugal pump is the place where the pressure is lowest. If the local pressure is equal to or lower than the temperature in the vapor pressure of liquid, gas and steam will be dissolved in the liquid from the liquid in a large number of escape, forming many mixed steam and gas bubbles. These small bubbles with the liquid flow to high pressure areas, due to air bubbles within and around the bubble is greater than the vaporization pressure, vaporization pressure, pressure difference. Under the pressure difference, the bubble burst and re condensed. In the condensation process, the liquid particles from all around to the bubble center to accelerate movement, in the condensation of the moment, the particles collide with each other, resulting in a high local pressure. These bubbles, if they break down near the metal surface, are condensed, and the liquid mass is like a myriad of small bullets, hitting on the surface of the metal. Under high pressure and high frequency, the surface of the metal is gradually destroyed by fatigue, which is often referred to as erosion. In the bubble generated by the inclusion of a number of active gases (such as oxygen, etc.), with the heat released by the bubble condensation, the metal from the chemical corrosion. Chemical corrosion and mechanical erosion of the common role, it is more accelerated the speed of metal damage, this phenomenon is the phenomenon of cavitation damage. 
At the beginning of the centrifugal pump cavitation, the cavitation area is small, the normal work of the pump has no obvious effect, and there is no obvious reflection of the pump performance curve. But when cavitation develops to a certain extent, the bubbles produced, affecting the normal flow of liquid, and even cause the liquid flow interruption, vibration and noise; at the same time, pump flow, head and efficiency decrease, is also apparent in the pump performance curve. Serious when the pump can not work. In order to avoid cavitation phenomenon, in the process of design, should make the liquid in the pump before the degree of cooling, at the same time the pump should be installed in the lower position, so that the liquid inlet has a certain static pressure head. In addition to pay attention to the cold, as far as possible to reduce the loss of cold. 

2017年2月6日星期一

Installation instructions of horizontal centrifugal pump

1.In the installation, you need to check parts, such as motor, water pumps, etc., especially the pipeline, whether there are impurities affect the operation, to avoid damage to the parts when working. 
2.In order to maximize the performance of the equipment to play, and as far as possible to extend the use of equipment, installation of pipeline equipment should have different support. 
 
3.Due to the temperature limit, in the transmission of high temperature liquid, in order to ensure the pipeline with the force, in the early installation, the bottom bolt is not fixed, and then the pipeline with the temperature change and synchronous movement. 
 
4.Import and export flange specifications need to be consistent with the pipeline configuration specifications. 
 
5.The installation should be installed at the entrance of a filter to avoid the debris into the pump and affect the efficiency of the work or damage to the equipment. In addition, the outlet of the check valve should be installed outside. 
 
6.Due to the scope of application of the centrifugal pump may be in the suction range, so the import and export pipeline to minimize the twists and turns, to ensure that there will be no leakage of water vapor phenomenon. 
 
7.For the whole work and maintenance process can be carried out smoothly, at the time of installation, the inlet and outlet pipe to install a separate regulation and pressure testing equipment to ensure the timely detection and treatment of abnormal situation. 
 
8.A full set of installation is completed, start the test, check whether there is friction and the card dead phenomenon, OK no problem can be put into use. 

The reason and solution of the shortage of the centrifugal pump flow

1.Import and export pipeline, flow of centrifugal pump impeller partially blocked, the scale deposition in the pump inside. Check the pipe and pump cavity to remove the blockage, re adjust the valve size. 
2.The voltage is low. The solution to the problem of centrifugal pump flow: stable voltage. 
 
3.Centrifugal pump impeller wear. Solution: replace the new impeller. 
 
4.Is not the above several reasons please according to the following centrifugal pump does not water the reason comprehensive inspection. 
 
5.The centrifugal pump inlet or outlet valve is not open, the inlet pipe is blocked, the pump cavity impeller flow channel is blocked. Check whether the import and export of the valve is closed to open the closed valve, check the inlet and outlet pipes and pump impeller is a debris blockage removal. 
 
6.The motor's running direction is not right, the motor phase speed is very slow. Change the motor wiring to adjust the motor's turn, check the power supply into the wire fastening good motor wiring. 
 
7.The centrifugal pump inlet pipe leakage, leading to the centrifugal pump has been in the state of air suction. Check the leakage point of the imported pipeline leak to repair the leak, tighten the cover, remove the air. 
 
8.The centrifugal pump is not filled with liquid, the pump cavity has air. Unscrew the pump cover or open the exhaust valve and discharged into the air. 
 
9.The centrifugal pump inlet pipeline centrifugal pump water flow lack the required flow, or suction is too high, the inlet pipe valve centrifugal pump seal is not good Water Leakage. Check the pump (pipe network and the use of water pipe with the suction process is prone to this phenomenon), adjust the distance to shorten the distance, or replace the self suction pump. 10, pump outlet pipe resistance is too large, pump selection is not appropriate or the pump head can not reach. Reduce the pipe bend, bend too much can be installed on the automatic exhaust valve, exclude the pipeline corner of the condensation of air, or re election pump

2017年2月5日星期日

How to solve the problem of horizontal multi-stage pump

1.Horizontal multi-stage pump does not absorb water or water. The cause of this failure is mostly due to the end of valve stuck, part of the blockage of water, high water or water pipe leakage is too high. Should be checked one by one, taken at the end of valve repair, clear the blockage and correct the steering and other processing. 
 
2.Pipeline leakage or leakage. No more than nuts tightened due. If the leakage is not serious, can be applied to cement slurry, mud or soft soap in the leakage; if the joints Water Leakage, tighten the nut wrench can be used. Serious leakage, leakage, must be re assembled. 
 
3.Multi-stage centrifugal pump severe vibration. May be the motor rotor is not balanced or shaft coupling. Sometimes bearing wear, bending, rotating parts of the relaxation, rupture, pipeline stent is not strong also cause vibration. Should be adjusted, reinforcement, inspection or replacement. 
 
4.The impeller is bad. When the damage is not large, can be repaired. Hard alloy should be replaced or plated when the damage is serious. Completely damaged, the impeller should be removed, the repair shop to repair. 
 
5.Horizontal multi-stage pump shaft bending. Is due to the impact load, belt pulled too tight, causing incorrect installation. If the bend is not serious, can be used manually screw to correct, but not too hard, in case of a complete break.